MAX4080SASA

Manufacturer: MAXI

76V / High-Side / Current-Sense Amplifiers with Voltage Output

Partnumber Manufacturer Quantity Availability
MAX4080SASA MAXI 100 In Stock

Description and Introduction

76V / High-Side / Current-Sense Amplifiers with Voltage Output The MAX4080SASA is a high-side current-sense amplifier manufactured by Maxim Integrated (now part of Analog Devices). Below are its key specifications, descriptions, and features based on the available knowledge:

### **Specifications:**  
- **Manufacturer:** Maxim Integrated (MAXI)  
- **Part Number:** MAX4080SASA  
- **Package:** 8-pin SOIC (Small Outline Integrated Circuit)  
- **Supply Voltage Range:** +4.5V to +28V  
- **Input Common-Mode Voltage Range:** +4.5V to +28V  
- **Gain Options:**  
  - MAX4080T: 20V/V  
  - MAX4080F: 50V/V  
  - MAX4080S: 100V/V  
- **Bandwidth:** 250kHz (typical)  
- **Accuracy:** ±1% (max) gain error  
- **Quiescent Current:** 100µA (typical)  
- **Operating Temperature Range:** -40°C to +125°C  

### **Description:**  
The MAX4080SASA is a precision, high-side current-sense amplifier designed for monitoring current in applications such as power management, battery charging, and motor control. It provides a ground-referenced output proportional to the current flowing through an external sense resistor.  

### **Features:**  
- **High-Side Current Sensing:** Eliminates the need for a low-side resistor.  
- **Wide Input Voltage Range:** Supports up to +28V common-mode voltage.  
- **Low Offset Voltage:** Ensures accurate current measurement.  
- **Low-Power Operation:** Ideal for battery-powered applications.  
- **Fixed Gain Options:** Available in 20V/V, 50V/V, and 100V/V variants.  
- **Rail-to-Rail Output:** Provides full dynamic range.  
- **Robust Design:** Operates in harsh environments (-40°C to +125°C).  

For detailed application notes or further technical details, refer to the official datasheet from Maxim Integrated (Analog Devices).

Application Scenarios & Design Considerations

76V / High-Side / Current-Sense Amplifiers with Voltage Output# Technical Documentation: MAX4080SASA High-Side Current-Sense Amplifier

## 1. Application Scenarios

### 1.1 Typical Use Cases
The MAX4080SASA is a high-side current-sense amplifier designed for precision current monitoring in systems where direct ground-referenced measurements are impractical. Its primary function is to amplify small differential voltages developed across a shunt resistor placed in the power supply path, converting this measurement into a ground-referenced output voltage proportional to the load current.

 Key operational scenarios include: 
-  Battery-powered systems : Monitoring charge/discharge currents in portable electronics, power tools, and backup systems
-  Motor control circuits : Real-time current feedback for brushed/brushless DC motor drivers in robotics and automotive systems
-  Power supply units : Overcurrent protection and load monitoring in DC-DC converters and voltage regulators
-  LED lighting systems : Constant current regulation and fault detection in high-power LED arrays
-  Telecom infrastructure : Current monitoring in -48V power distribution for base stations and networking equipment

### 1.2 Industry Applications

 Automotive Electronics: 
- Electric vehicle battery management systems (BMS)
- Electronic power steering current monitoring
- Advanced driver assistance systems (ADAS) power monitoring
- 12V/24V/48V automotive bus current sensing

 Industrial Automation: 
- PLC I/O module current monitoring
- Servo drive current feedback
- Industrial motor overload protection
- Process control instrumentation

 Consumer Electronics: 
- Smartphone/tablet battery fuel gauging
- USB power delivery (PD) current monitoring
- Laptop power adapter load detection
- Gaming console power management

 Renewable Energy: 
- Solar panel string current monitoring
- Wind turbine generator current sensing
- Energy storage system current measurement

### 1.3 Practical Advantages and Limitations

 Advantages: 
-  High-side operation : Eliminates ground path disruption, maintaining system integrity
-  Wide common-mode range : Operates from +4.5V to +76V, accommodating various power rails
-  Low offset voltage : Typically ±500µV maximum ensures accurate low-current measurements
-  Integrated gain resistors : Factory-trimmed for precise gain (20V/V, 60V/V, or 100V/V versions)
-  Small footprint : 8-pin SOIC package saves board space
-  Low quiescent current : Typically 60µA minimizes power consumption in battery applications

 Limitations: 
-  Fixed gain options : Limited to specific gain values (no user-adjustable gain)
-  Bandwidth constraints : 140kHz typical bandwidth may limit high-frequency current monitoring
-  Temperature dependence : Gain drift of ±15ppm/°C typical requires consideration in precision applications
-  Single-supply operation : Cannot handle negative common-mode voltages
-  Limited output drive : 5mA maximum output current may require buffering for some ADC interfaces

## 2. Design Considerations

### 2.1 Common Design Pitfalls and Solutions

 Pitfall 1: Shunt Resistor Selection 
-  Problem : Inappropriate shunt value causes either excessive power dissipation or insufficient signal
-  Solution : Calculate optimal shunt using: RSHUNT = (VFS_MAX × Gain) / IMAX, where VFS_MAX is typically 100mV for best accuracy

 Pitfall 2: Input Filtering Issues 
-  Problem : Excessive filtering capacitors create stability problems
-  Solution : Limit differential filter capacitors to ≤ 1nF and ensure common-mode capacitors are balanced

 Pitfall 3: Layout-Induced Errors 
-  Problem : Poor Kelvin connection to shunt resistor introduces measurement errors
-  Solution : Implement true 4-wire connection with separate sense traces directly to shunt pads

 Pitfall 4: Overvoltage

Alternative Part Number

  • INA181A1IDBVR --: High-side current sense amplifier with similar gain and function, widely available and cost-effective alternative.
  • AD8210YRZ --: High-side current shunt amplifier offering comparable performance and accuracy for current sensing applications.
  • LT6105IMS8 --: Precision current sense amplifier with similar functionality and wide input common-mode range.
  • INA199A1RSWT --: Current-sense amplifier with similar high-side sensing function and small package, a common cross-vendor substitute for the MAX4080 family.

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips